MODEL AM3-SM
NETWORK I/O FOR MODBUS
AddMe® III for Modbus
|
|
|
|
|
Model AM3-SM
Programmable I/O for Modbus
• 18 Analog/Universal Inputs
• 4 Analog Outputs
• 8 Discrete Outputs
• 2 Discrete/Pulse Inputs
Modbus RTU Slave
|
|
|
|
|
AddMe III Programmable I/O with Modbus RTU
Order code: 00AM3SM
|
List:
$850.00 |
Your price:
$680.00 |
Log In for
Wholesale |


|
Control Solutions’ AddMe III features 18 universal inputs which are context sensitive. When configured as an analog input, the continuously self-calibrating sigma-delta converter produces 15-bit resolution with high noise immunity. When configured as a discrete input, the converter switches to 8-bit resolution at 128 samples per second for fast response. All I/O points are accessed as Modbus holding registers.
Floating point holding registers provide data from the analog I/O points. In addition, analog (universal) inputs are mirrored to integer registers and may be treated as on/off values. Linearization tables are provided for 10K and 20K type II, III, and IV thermistors. Input type and scaling is configured by writing to additional holding registers.
• 18 Analog/universal inputs
- - - 0-10VDC, Thermistor, dry contact
- - - Software selectable input type
- - - 0.1% reference, up to 16-bit resolution
- - - Continuously self-calibrating sigma-delta converter
• 4 Analog outputs
- - - 4-20mA (0-20mA)
- - - 8-bit resolution
• 8 Discrete outputs
- - - Form A relay, 5A @ 120VAC
- - - HOA switches & LED status indicators
• 2 Pulse/Discrete inputs
- - - TTL to 24VDC
- - - Rate or totalizing count input
• Modbus RTU RS-485 Slave
• Powered by 18-30VDC or 24VAC 50/60 Hz
• Power Consumption:
- - - 0.3A @ 24VDC max.
• DIN rail mounting, 100mm H x 155mm W x 60mm D
• LED indicators for power, RS-485 RX, TX & error
• Pluggable screw terminal blocks
• Operating temperature -30°C to +70°C
• Humidity 5% to 90%
• FCC Class A, CE Mark
|
|
|
| The online support package you download right here for free includes help pages in browser format, JavaScript sensor calibration tool, Windows device configuration tool, and PL/i compiler. To review the help pages, just click the image above. To download, go to the Downloads page.

|
| AddMe III is freely programmable using Control Solutions' PL/i language. The PC based compiler is part of the free configuration tool you download from this web site.
AddMe III model AM3-SM is simply an I/O node on the Modbus network until you download a program code file. The program is saved in Flash, and AddMe III now becomes a stand alone controller (still a slave on the network).

|
| You can configure AddMe III manually by writing to Modbus registers. The free Windows based configuration tool figures out the registers for you. You simply select options from lists. Click the image below to see the tool close up. |
|
|

|