If you need to connect one or more Modbus RTU devices to a LonWorks network, you found the right product here!
|
How do you configure the gateway? If you recognize 40001 as a reference to a holding register, you've got it figured out. Just type it in.
|
 |
Control Solutions’ Babel Buster 485 is a fully configurable universal LonWorks to Modbus RTU gateway. The RTU master is used to make Modbus RS-485 devices accessible on a LonWorks network. The RTU slave is used to make LonWorks devices accessible on a Modbus RS-485 network. The Babel Buster 485 gateway is designed to be economical enough to use multiple gateways, one per device or group of devices, rather than run parallel networks to a larger, more expensive gateway.
An RTU master Babel Buster 485 can poll multiple Modbus slaves, and can be bound to any number of LonWorks devices. An RTU slave Babel Buster 485 responds to a single Modbus slave unit ID, and may be bound to any number of LonWorks devices. LonWorks network variable data is translated to Modbus register data, and vice versa. Modbus polling rates and LonWorks network update rates are fully configurable. Register mapping and network variable types (SNVT) are fully configurable.
The LonMark Certified Babel Buster 485 conforms fully to LonMark version 3.3. The only tool required to configure Babel Buster is LonMaker version 3.
• Universal, fully configurable
• You pick the Modbus register
• You pick the SNVT type
• No extra software or drivers to buy
• LonWorks TP/FT-10 (FTT-10A) to Modbus RS-485 Gateway
• Translate 58 LonWorks network variables to Modbus registers
• LonMark Ver. 3.3 Sensor & Actuator Functional Profiles
• Supports Modbus “coils”, input registers, and holding registers
• Single or double Modbus registers, signed, unsigned, IEEE 754
• All scalar LonMark SNVT types supported including floating point
• SNVT_switch & SNVT_state also supported
• SNVT types dynamically assignable via LonMaker
• Modbus register mapping dynamically mappable via LonMaker
• Modbus registers may be scaled (x10, x100, x0.1, x0.01, etc.)
• Min/max send time, send on delta configurable per point
• Modbus (master) polling interval configurable per point
• Object override supported on point by point basis
• Bidirectional communication between LonWorks and Modbus
• LonMark certified, version 3.3
• 3150L Neuron® Chip, 48K Flash memory, 10K RAM
• TP/FT-10 (FTT-10A) transceiver
• Powered by 10-30VDC or 12-24VAC 50/60 Hz
• Power Consumption: 0.1A @ 24VDC
• DIN rail mounting, 100mm H x 70mm W x 60mm D
• Modbus standard RJ-45 connector, RS-485 pin-out
• LED indicators for LonWorks & Modbus status
• Pluggable screw terminal block for power & LonWorks network
• Operating temperature -40°C to +85°C
• Humidity 5% to 90%
• FCC Class B
• CE Mark
| BB485 |
Babel Buster 485 Modbus RTU to LonWorks Gateway |
$319.00 |
|
|