Detailed Product Listing
BABEL BUSTER BB2-7010-01
NETWORK GATEWAY

Babel Buster® BB2-7010-01 (IP/XM)

BACnet IP to Modbus Gateway

Maps Modbus RTU or TCP registers to BACnet IP as Analog, Binary, or Multi-State Objects!

• Modbus RTU master & slave
• Modbus TCP client & server
• BACnet IP client & server
• COV support in BACnet IP server





Babel Buster BB2-7010-01 Modbus to BACnet IP Gateway

Order code BB2-7010-01

List:
$699.00
Your price:
$559.00
Log In for
Wholesale
The SNMP version of the BB2-7010 is now available. This gateway uses SNMP Get requests to obtain data from SNMP devices commonly found in data center power equipment.

Note to IP/XM Users: The BB2-7010 is functionally identical, and your configuration files will work as is. Other than cosmetic enhancements, the changes are in hardware with additional indicators and a hardened EIA-485 port that will withstand accidental cross wiring between data and 24V power.

Babel Buster BB2-7010-01 (formerly Babel Buster IP/XM) contains three different clients and three different servers. The BB2-7010 includes BACnet/IP client and server, Modbus TCP client and server (master and slave), and Modbus RTU master and slave.

The BACnet IP client allows BACnet IP devices to be accessible from Modbus TCP or RTU. You configure the device instance, object type and instance, and poll interval for reading or writing BACnet objects. The object data is stored in the BB2-7010 server for subsequent retrieval by any supported remote client (or master).

A large number of BACnet objects gives you flexibility in mapping Modbus registers to any combination of BACnet objects. Packed Modbus registers may be parsed to multiple BACnet objects when reading. Multiple BACnet objects may be packed into a single Modbus register when writing. All standard Modbus register types are supported.

Value objects will poll their assigned Modbus register at the interval you specify. The content of the Modbus register will be given as the Present Value of the BACnet object when read. The Modbus register is written each time the BACnet Value object is written. The Value object corresponds well with the Modbus Holding register.

Input objects will poll their assigned Modbus register at the interval you specify, and provide the Modbus data as the Present Value when read. Commandable Output objects are used to write Modbus registers, and will update the Modbus device each time BACnet is updated.

The same polling schemes that apply to Modbus also apply to remote BACnet IP slaves polled by the BB2-7010's BACnet IP client.

• Universal, fully configurable
• No extra software or drivers to buy

• Read/Write any standard Modbus register via BACnet
• Read/Write any standard BACnet object via Modbus
• Bidirectional communication between BACnet and Modbus
• Supports Modbus “coils”, input registers, holding registers
• Single or double Modbus registers
• Signed, unsigned, IEEE 754
• Modbus register mapping configured via web interface
• Modbus registers may be scaled (x10, x0.1, etc.)
• Modbus (master) polling interval configurable per point
• Commandable BACnet objects implement priority array
• Hardened EIA-485 transceiver for Modbus RTU
• 10/100BaseT Ethernet for BACnet IP and Modbus TCP
• Powered by 10-30VDC or 12-24VAC 50/60 Hz
• Power Consumption: 0.1A @ 24VDC
• DIN rail mounting, 100mm H x 70mm W x 60mm D
• Pluggable screw terminal block for power & RTU network
• Operating temperature -40°C to +85°C
• Humidity 5% to 90%
• FCC Class A, CE Mark
• Listed to UL 916 and (Canadian) C22.2 No. 205-M1983

Support for Mod10 format (2, 3, and 4-register) is now included in this gateway.

The User Guide, and Flash videos to help you get started, may be found on the Enhanced Support Page.

A demo copy of the embedded web site contained within the Babel Buster BB2-7010 is found at the link above. Visit this link for object property summary and hardware guide, in addition to the demo copy of device configuration pages.

All configuration is done via the web pages, eliminating the need for special configuration properties for each object.

• Connect Modbus devices to
a BACnet IP network

• Connect BACnet IP devices to
a Modbus network

• Includes BBMD support

Click here for the SNMP version of the Babel Buster BB2-7010