General Product Information


Products Recently Released
(last updated 21-August-2010)

Babel Buster® BB2-6040-XSC Modbus to Wireless Gateway

● Modbus RTU and Modbus TCP gateway for virtually unlimited number of 900 MHz XSC sensors from Point Six Wireless
● Modbus RTU master or slave, Modbus TCP client and server
● Highly customizable with Script Basic for manipulation of any combination of sensors
● User customizable HTML web interface for viewing data remotely
● Web portal support for alarm notification via SMS, email, voice calls using service such as LogMyData.com

Babel Buster® BB2-6010 Modbus to SNMP Gateway

• Modbus RTU RS-485 Master or Slave
• Modbus TCP Client and Server
• Modbus TCP over Ethernet 10/100BaseT
• SNMP get/set access to all data points
• SNMP trap generation, user programmable criteria
• Hardened EIA-485 transceiver for Modbus RTU
• Functionally identical to Babel Buster SPX, but in a DIN rail package

Babel Buster® BB2-7040 BACnet to ZigBee Gateway

• BACnet Server to put ZigBee devices on BACnet network
• BACnet MS/TP and BACnet IP in one gateway
• BACnet Client for reading/writing other BACnet devices
• BACnet server includes COV subscription support
• Analog, Binary, Multistate types of Input, Output, Value objects
• Up to 400 BACnet objects mapped to up to 100 ZigBee devices
• Hardened RS-485 port for BACnet MS/TP
• Auto-sense 10/100BaseT Ethernet for BACnet IP
• Embedded web server for configuration and diagnostics

Babel Buster® BB2-3010 BACnet MS/TP to Modbus RTU

• BACnet Server (slave) to put Modbus RTU devices on MS/TP network
• Modbus RTU Master for reading/writing Modbus RTU devices
• BACnet Client for reading/writing BACnet MS/TP devices
• Modbus RTU Slave for MS/TP access to PLC, or Modbus access to MS/TP
• BACnet server includes COV subscription support
• Analog, Binary, Multistate types of Input, Output, Value objects
• Up to 300 objects, object types fully configurable
• Hardened RS-485 ports for MS/TP and RTU

MTX002 USB to MS/TP Port Adapter

• Intelligent adapter connects MS/TP network via PC's USB port
• Reliable connection off-loads token passing from PC
• Appears as another MS/TP device on the network
• Supports 9600 through 76800 baud
• Supports configuration tools for Babel Buster 2 and ValuPoint products
• Can be used with MS/TP packet capture for Wireshark analysis
• Can be used in pass-through mode for Modbus RTU diagnostics

i.CanDrawIt® Graphical Programming

Graphical Programming and Simulation for BACnet, Modbus, LonWorks, SNMP

It goes by a few different names: Graphical programming, visual programming, visual control, etc. When we say graphical programming, we mean you simply draw a picture of your control program, compile it with a couple of mouse clicks, and download it to the controller or freely programmable network I/O. Simulation and debugging is also done graphically. Supported by most Control Solutions products.

Babel Buster® BB2-7010 BACnet IP to SNMP Gateway

• Includes BACnet Client for reading/writing BACnet IP devices
• Includes Modbus TCP Client for reading/writing Modbus TCP devices
• Includes Modbus RTU Master for reading/writing Modbus RTU devices
• Includes SNMP Client for reading/writing SNMP agents
• Can generate SNMP v2c Traps

• BACnet server lets you put this device on your BACnet IP network
• Modbus TCP server lets you put this device on your Modbus TCP network
• Modbus RTU slave lets you put this device on your Modbus RTU network
• SNMP server (agent) lets you put this device on your SNMP network
• BACnet server includes COV subscription support
• Analog, Binary, Multistate types of Input, Output, Value objects