Convert BACnet IP or MS/TP to SNMP

BBPRO-V230 SNMP to BACnet IP Gateway

Babel Buster

Pro V230

Babel Buster Pro V230 is the most intelligent connection yet between BACnet and SNMP v1 or v2c. The Pro V230 features an automatic table walker and flexible trap receiver that fully supports connecting BACnet to a UPS with an RFC 1628 MIB. Built-in Script Basic with SNMP enhancements provide even greater power and flexibility. The Pro V230 includes BACnet IP and BACnet MS/TP client and server. The Pro V230 includes SNMP client and server, and can send or receive traps. An optional version (-SP) can be programmed to convert proprietary serial protocols to BACnet IP and SNMP.

Learn more...

Convert BACnet MS/TP to Modbus RTU

BB2-3010 BACnet MS/TP to Modbus RTU Gateway

Babel Buster

BB2-3010

Babel Buster BB2-3010 is a fully configurable universal Modbus RTU to BACnet MS/TP gateway. The Babel Buster BB2-3010 is an RTU master used to make multiple Modbus RTU RS-485 devices accessible on a BACnet network. The BB2-3010 is also capable of acting as a BACnet MS/TP client and Modbus RTU slave, allowing BACnet devices to be connected to a Modbus network. The BB2-3010 can also be MS/TP slave and Modbus slave at the same time for putting industrial PLC's on a BACnet network.

Learn more...

Convert Modbus TCP to BACnet MS/TP

BB2-3060 Modbus TCP to BACnet MS/TP Gateway

Babel Buster

BB2-3060

Babel Buster BB2-3060 is a fully configurable universal Modbus TCP to BACnet MS/TP gateway. The Babel Buster BB2-3060 is a TCP client (master) used to make multiple Modbus TCP devices accessible on a BACnet network. The BB2-3060 is also capable of acting as a BACnet MS/TP client and Modbus TCP server (slave), allowing BACnet devices to be connected to a Modbus network. The BB2-3060 can also be MS/TP slave and Modbus slave at the same time for putting industrial PLC's on a BACnet network.

Learn more...

Convert BACnet IP to Modbus RTU and TCP, Convert BACnet IP to SNMP, Connect BACnet to WiFi Sensors.

BB2-7010 BACnet IP to Modbus RTU and TCP Gateway

Babel Buster

BB2-7010

Babel Buster BB2-7010 contains up to five different clients and four different servers. The BB2-7010-01 includes BACnet/IP client and server, Modbus TCP client and server (master and slave), and Modbus RTU master and slave. Modbus devices are accessible from BACnet IP and vice versa. The BB2-7010-02 and additional models also include an SNMP client and server (agent), making BACnet data accessible via SNMP or making SNMP devices accessible from BACnet. Additional models include support for collecting data from third party WiFi sensors and controlling WiFi actuators.

Learn more...


BACnet IP to MS/TP Router, Remap BACnet Objetcts, Convert BACnet to Modbus TCP, SNMP

BB2-7030 BACnet IP to MS/TP Router

Babel Buster

BB2-7030

Babel Buster BB2-7030 is a BACnet IP to MS/TP Router, configured or learning, that will route BACnet IP to MS/TP and vice versa via its local ports, and supports full router capability for multi-hop internetworks including via NAT WAN routers. The BB2-7030 is also a client/server gateway that allows remapping BACnet objects from multiple slaves into one master. The gateway also features support for Modbus TCP or SNMP to MS/TP, includes BBMD support, and includes proxy support.

Learn more...

Convert BACnet MS/TP to LonWorks

BB2-3020-NB BACnet MS/TP to LonWorks Gateway

Babel Buster

BB2-3020-NB

Babel Buster BB2-3020-NB is a BACnet MS/TP slave (server) device that functions as a LonWorks device manager. NV Structures may be parsed to multiple BACnet objects when reading. Multiple BACnet objects may be packed into a single structured variable when writing. All standard SNVT’s are supported. Objects mapped to Network Variable Outputs (NVO) will poll their assigned variable at the interval you specify. Network Variable Inputs (NVI) are written each time the mapped BACnet object is written.

Learn more...

Convert BACnet IP to LonWorks

BB2-7020-NB BACnet IP to LonWork Gateway

Babel Buster

BB2-7020-NB

Babel Buster BB2-7020-NB is a BACnet IP slave (server) device that functions as a LonWorks device manager. NV Structures may be parsed to multiple BACnet objects when reading. Multiple BACnet objects may be packed into a single structured variable when writing. All standard SNVT’s are supported. Objects mapped to Network Variable Outputs (NVO) will poll their assigned variable at the interval you specify. Network Variable Inputs (NVI) are written each time the mapped BACnet object is written.

Learn more...

Connect BACnet IP to Proprietary Serial ASCII

Babel Buster SP Custom BACnet IP to Proprietary Serial Gateway

Babel Buster

BBSP-Custom

Babel Buster SP Custom lets you create your own gateway. Designed to interface devices with a proprietary RS-232 ASCII protocol, the proprietary part of the protocol is user programmed using the built-in Script Basic. Simple function calls are provided to move data between your Basic program and BACnet IP objects. The BACnet IP side of this gateway is the same as our other BACnet IP gateways, and is configured via the internal web server.

Learn more...